Agua Pura

Parameters of Quality Water

These are the reference values used to judge the quality of drinking water.

ParameterReference valueRemark
pH6.5 – 8.5Osmosis water often comes out slightly acidic; it is corrected when remineralizing.
Total dissolved solids (TDS)< 300 mg/L (excellent per WHO); Peru limit: 1000 mg/LOsmosis leaves water almost free of minerals (very low TDS).
Electrical conductivityPeru limit: 1500 µS/cmMeasures dissolved ions and is the inverse of resistivity. Ultrapure water (18.2 MΩ·cm) is not the goal for drinking.
Hardness (as CaCO₃)Comfort: 50–150 mg/L; Peru limit: 500 mg/LNo WHO health-based guideline; affects taste.
Calcium and magnesiumCommon targets when remineralizing: Ca 20–40 mg/L, Mg 10–20 mg/LIndicative values, to be confirmed with a laboratory.
Turbidity< 1 NTU (Peru limit: 5 NTU)Low turbidity is needed for UV light to work effectively.
Free chlorineWHO guideline value: up to 5 mg/LRemoved here; with no residual chlorine, hygiene during bottling is critical.
Nitrate50 mg/L (WHO and Peru)Guideline value intended to protect infants.
Arsenic and lead0.01 mg/L each (WHO and Peru)Metals that pose long-term health risks.
MicrobiologyThermotolerant coliforms: 0 CFU/100 mL; heterotrophic bacteria ≤ 500 CFU/mL (Peru)Verified through regular laboratory testing.
Redox potential (ORP)No regulatory valueClaims that a negative ORP is beneficial have no scientific backing.

Reference values from the WHO and D.S. 031-2010-SA (Peru). Bottled water may be subject to additional requirements.