Parameters of Quality Water
These are the reference values used to judge the quality of drinking water.
| Parameter | Reference value | Remark |
|---|---|---|
| pH | 6.5 – 8.5 | Osmosis water often comes out slightly acidic; it is corrected when remineralizing. |
| Total dissolved solids (TDS) | < 300 mg/L (excellent per WHO); Peru limit: 1000 mg/L | Osmosis leaves water almost free of minerals (very low TDS). |
| Electrical conductivity | Peru limit: 1500 µS/cm | Measures dissolved ions and is the inverse of resistivity. Ultrapure water (18.2 MΩ·cm) is not the goal for drinking. |
| Hardness (as CaCO₃) | Comfort: 50–150 mg/L; Peru limit: 500 mg/L | No WHO health-based guideline; affects taste. |
| Calcium and magnesium | Common targets when remineralizing: Ca 20–40 mg/L, Mg 10–20 mg/L | Indicative values, to be confirmed with a laboratory. |
| Turbidity | < 1 NTU (Peru limit: 5 NTU) | Low turbidity is needed for UV light to work effectively. |
| Free chlorine | WHO guideline value: up to 5 mg/L | Removed here; with no residual chlorine, hygiene during bottling is critical. |
| Nitrate | 50 mg/L (WHO and Peru) | Guideline value intended to protect infants. |
| Arsenic and lead | 0.01 mg/L each (WHO and Peru) | Metals that pose long-term health risks. |
| Microbiology | Thermotolerant coliforms: 0 CFU/100 mL; heterotrophic bacteria ≤ 500 CFU/mL (Peru) | Verified through regular laboratory testing. |
| Redox potential (ORP) | No regulatory value | Claims that a negative ORP is beneficial have no scientific backing. |
Reference values from the WHO and D.S. 031-2010-SA (Peru). Bottled water may be subject to additional requirements.